Low Noise Dental Handpieces And Accessories / Dental Low Speed Handpiece With CE Standard

Packaging Details : 1 set / box Delivery Time : depending on the quantity and sizes
Payment Terms : T/T, Western Union,Paypal
Place of Origin: Shenzhen , China Brand Name: OEM
Certification: CE

Detail Information

Quantity: 1 Set / Box Hole: 2 / 4 Holes
Noise: <=70dB Working Pressure: 0.30Mpa-0.35Mpa
Speed: 22,000-27,000 Rpm Payment: T/T, Western Union, Paypal
High Light:

dental lab material

,

dental handpiece parts

Product Description

Dental Low Speed Handpiece Kit Dental Handpiece Repair Kit, Dental External Kit


Features:

 

Contra angle handpiece


Low Speed 22,000-27,000 rpm


The shank of the instrument mounted therein is 2.35 mm


Fastening of the instruments with a turning latch


Autoclavable 135°C


For any lab or E-type motors

 

Color Style Silver
Chuck  Key Type
Spray External water spray
Hole 2 or 4 Holes
Air Pressure 0.3-0.35Mpa
Rotation Speed 14,000-22,000 rpm
Noise ≤65 dB

 

Straight Handpiece


Working pressure: 0.3MPa


0.25MPa(Measure meter is installed at the end of air motor to measure the air pressure)


Revolution: about 22000-27000r/min (adjustable between clockwise or anticlockwise)


Noise: ≤70dB


Air consumption: about 56L/min


Ratio: 1:1


Max speed of contra angle: 25000rpm/min

 

Air Motor:


Supply air pressure: 245-392KPa (2.5-4kgf/CM2)


1:1 Direct Drive


Borden 2 holes/Midwest 4 holes


Max speed 20,000 min-1

 
Air-in Pressure(kg/cm2) Motor Rotation(rpm) Air Wastage:(N1/min)
2.5 22,000 42
3 25,000 51
4 27,000 72

 

WAYS OF LOADING AND UNLOADING BURS:


(1). Straight handpiece: When unloading the bur, please turn the stuck, until you hear a sound.

And loading the bur, you turn the stuck to the opposite side. When you hear a sound, the bur has been fixed

 

(2). Contra angle handpiece: Screw the clip and put the bottom of bur to the axle center, then turn the clip to the original place.

Unloading the bur, screw the clip and take the bur out.

 

CLEAN AND LUBRICATE:


(1). Air motor: Load the pipe from motor. For example drip some lubrication into the air pipe at the bottom.

Lubricate it after every use, drip 2 drops.
(2). Straight handpiece: Turn the spray head to the mouth of lubrication.When unloading the bur, put the spray head to the handpiece and ensure that the head of handpiece show sigh of oil.(at least 2 seconds). Don't invert oil tin when using lubrication.


(3). Contra angle handpiece: Loose the winding part of SH, take the conducting gear out. Lubricate the conducting part.Screw the clip when lubircating the head of handpiece. 

 

CAUTIONS:


Don't use damaged or winding burs. The damaged or winding burs will cause accident if use.


Burs are hard to pull out if the gully part has damaged.


Please keep the clamping part clean, if it was stained, the cartridge will shock or the strength of clamping part will weaken.


Please fix the burs, or the bearings will be damaged at early stage. Don't use motor when the clip is loose or burs are not on.


Please install the burs or standard stick even not in usage.

 

Payment :

 

T/T, Western union, Paypal

 

Packing :

 

It includes Contra Angle Handpiece,Straight Handpiece With Air Motor

 